Any cooking of food carried out during a special eventusing a device powered by gas or charcoal.
- Any device used to cook food must be approved and must comply with the manufacturer's specifications or be designed for that purpose.
- No cooking equipment or fuel-burning appliance may be used in a tent or inflatable structure if it is accessible to the public.
- All shelters, awnings, umbrellas or other items erected over cooking appliances must comply with CAN/ULC-S109-M "Fire Tests for Flame-Resistant Textiles and Films" or NFPA-701 "Standard Methods of Fire Tests for Flame-Resistant Textiles and Films". The flame retardant certificate must be available on site.
- Flame retardant treatments shall be renewed as necessary to ensure that materials meet the match flame exposure test of NFPA 705, "Field Flame Test for Textiles and Films"t.
- Maintain a distance of at least 3 m between each kiosk providing food cooked on site and any other kiosk or tent.
- Install a hood that complies with regulations above the cooking devices, except for kiosks designed so that their longest wall is open over an area of at least 40%.
- Smoking is prohibited near the propane cylindersand "No Smoking" signs must be put up.
- The reserve propane cylinders must be well identified and stored in a safe place outside the tents or buildings.
- Maintain a distance of at least 400 mm between the deep fryer and the flames of an adjacent cooking device.
- Any warming tray using fuel must not be set on a paper tablecloth or a layer of plastic. Storage of combustible products in a public area must be limited to the appropriate volume for one day of operation.
- Maintain a distance of at least 600 mm between the cooking device and any other physical element or opening, such as a door, window or an air intake.
- If a charcoal-fired appliance is used, it must rest on a non-combustible surface and be at least 600 mm away from any combustible material. In addition, charcoal briquette ashes must be disposed of in a safe manner.
- Have an approved class 3A-10BC portable fire extinguisher near the cooking device as well as a class K fire extinguisher near the deep fryers.
- Any shelter, canopy, umbrella or other element that does not have a closed side and that is set up above a cooking device must be approved in accordance with standard CAN/ULC-S109-03.
- The propane cylinders must be at least 3 m from any commercial and industrial cooking devices. The cylinders must also be upright, must rest on a solid, level, fire-resistant base and must be attached. The cylinders must also be in good condition and have been used for no more than 10 years.
- Propane tanks must be installed outside the tent at least three (3) meters from the tent fabric.
The Régie du bâtiment contains information on the following:
- An event organizer's responsibilities
- Required permits
- Required certifications
- Required clearances
- Protecting gas pipes against damage
- The stability and protection of propane cylinders
- The type of food kiosk surface
- The required hood
- Required carbon monoxide detectors
- Required portable fire extinguishers
- Electricity